Clutch Wave-Plate Phase Difference Inspection - Honda Accord 2008 Manual

Hide thumbs Also See for Accord 2008:
Table of Contents

Advertisement

07/11/02 09:23:27 61TA0000_140_0364
Shafts and Clutches

Clutch Wave-plate Phase Difference Inspection

1. Place the clutch wave-plate (A) on a surface plate,
and set a dial indicator (B) on the wave-plate.
*01
2. Find the bottom (C) of a phase difference of the
wave-plate, zero the dial indicator and make a
reference mark on the bottom of the wave-plate.
3. Rotate the wave-plate about 60-degrees apart from
the bottom while holding the wave-plate by its
circumference. The dial indicator should be at the
top (D) of a phase difference. Do not rotate the
wave-plate while holding its surface, always rotate
it with holding its circumference.
4. Read the dial indicator. The dial indicator reads the
phase difference (E) of the wave-plate between
bottom and top.
Standard Phase Difference:
1st Clutch: 0.15 0.25 mm (0.006 0.010 in.)
2nd Clutch: 0.1 0.2 mm (0.004 0.008 in.)
3rd Clutch: 0.1 0.2 mm (0.004 0.008 in.)
4th Clutch: 0.1 0.2 mm (0.004 0.008 in.)
5th Clutch: 0.1 0.2 mm (0.004 0.008 in.)
5. Rotate the wave-plate about 60-degrees. The dial
indicator should be at the bottom of a phase
difference (F and G), and zero the dial indicator.
6. Measure the phase difference at the other two tops
(H and I) of the wave-plate by following steps 3 thru
5.
7. If two of the three measurements are within the
standard, the wave-plate is OK. If two of the three
measurements are out of the standard, replace the
wave-plate.
14-362
TA08AEBE10411212231MAAT00
B
E
C
I
D
F
H
A
G