Maintenance Objects
ad. Error Type 3901 — is used to give status information on a Far CSU
Loopback Test. The value in the Aux Data field indicates the status of the
loopback test.
Aux Data
1
2
3
4
ae. Error Type 3902 — is used to give status information on a One-Way Span
Test. The value in the Aux Data field indicates the status of the span test.
Aux Data
1
2
3
4
af. Error Type 3999 — indicates that the circuit pack sent a large number of
control channel messages to the switch within a short period of time. If
Error Type 1538 is also present, then the circuit pack was taken
out-of-service due to hyperactivity. If Error Type 1538 is not present, then
the circuit pack has not been taken out-of-service, but it has generated
50% of the messages necessary to be considered hyperactive. This may
be completely normal during heavy traffic periods. However, if this error
type is logged when the circuit pack is being lightly used, it may indicate a
problem with the circuit pack or the equipment attached to it.
1776
Issue 5 October 2002
Test Status
Currently running
Failed because loopback could not be activated
Failed because test pattern could not be detected
Terminated
Test Status
Currently running
Failed because test could not be activated
Test pattern was not received from the far end
Terminated