Avaya DEFINITY Server CSI Maintenance Manual page 1794

Table of Contents

Advertisement

Maintenance Objects
Table 530. TEST #138 Loss of Signal Alarm Inquiry Test — Continued
Error
Test
Code
Result
1324
FAIL
A non-service-affecting CSU Module/Sync Splitter audit failure was detected
by the UDS1 circuit pack. No ports should be affected. No immediate action
is required. These errors indicate that the CSU Module/Sync Splitter
hardware may have a problem, and that it should be replaced when practical
to avoid further deterioration.
1400
FAIL
Echo Canceller Function failed, this could be a hardware problem on the
TN464GP/TN2464BP:
1401
FAIL
Echo Canceller Function failed, this could be a hardware problem on the
TN464GP/TN2464BP:
PASS
DS1 signal is present and the physical link is healthy. In addition, no
Integrated CSU/Sync Splitter errors or echo cancellation errors are detected.
0
NO
The test could not relate the internal ID to the port (no board). This could be
BOARD
due to incorrect translations, no board is inserted, an incorrect board is
inserted, or an insane board is inserted.
This should re-establish the linkage between the internal ID and the port.
1794
Issue 5 October 2002
Description/ Recommendation
1. Issue the busyout board command.
2. Issue the test board long command.
3. Issue the release board command.
4. If Test 1420 still fails, replace the TN464GP/TN2464BP.
1. Issue the busyout board command.
2. Issue the reset board command.
3. Issue the test board long command.
4. Issue the release busy board command.
5. If the test still fails replace the TN464GP/TN2464BP.
1. Ensure that the board translations are correct. Execute the add ds1
UUCSS command to administer the UDS1 interface if it is not already
administered.
2. If the board was already administered correctly, check the error log to
determine whether the board is hyperactive. If this is the case, the board
is shut down. Reseating the board will re-initialize the board.
3. If the board was found to be correctly inserted in step 1, then issue the
busyout board command.
4. Issue the reset board command.
5. Issue the release busy board command.
6. Issue the test board long command.
Continued on next page