Maintenance Objects
Table 533. TEST #141 Yellow Alarm Inquiry Test — Continued
Error
Test
Code
Result
1
FAIL
The UDS1 interface circuit pack detected a remote multiframe alarm (RMA)
sent by the remote DS1 endpoint. An out of frame condition occurred at the
DS1 endpoint.
If the UDS1 connects to a T1 network facility or to another switch, do the
following:
If the UDS1 connects to a line-side terminating device (for example, a PRI
terminal adapter), do the following:
1806
Issue 5 October 2002
Description/ Recommendation
1. Verify that both endpoints of the DS1 link are administered using the
same signaling mode, framing mode, and line coding.
2. Contact T1 Network Service or a technician at the far-end switch to
diagnose the remote DS1 endpoint.
3. Check the physical connectivity of the UDS1 packs and of the cable.
4. Replace the local UDS1 interface circuit pack, and repeat the test.
1. Verify that the switch DS1 and the line-side terminating device are
administered using the same signaling mode, framing mode, and line
coding.
2. Investigate the maintenance status of the line-side terminating device.
Refer to the 'Line-Side Terminating Device Operating Manual' for
information.
3. Contact the vendor of the line-side terminating device to diagnose the
equipment.
4. Check the physical connection of the UDS1 interface circuit pack to the
terminating device, and check the premise distribution system (or the
intra-premise wiring) for physical connection failures.
5. Replace the local UDS1 interface circuit pack and repeat the test.