Avaya DEFINITY Server CSI Maintenance Manual page 1825

Table of Contents

Advertisement

UDS1-BD (UDS1 Interface Circuit Pack)
Table 539. TEST #1209 DS1 Board Loopback Test — Continued
Error
Test
Code
Result
2100
ABORT
Could not allocate the necessary system resources to run this test.
FAIL
UDS1 Interface circuit pack failed the DS1 Board Loopback Test.
PASS
The BLB test executed successfully. The test pattern was transmitted and
received successfully up to the DS1 board edge.
0
NO
The test could not relate the internal ID to the port (no board). This could be
BOARD
due to incorrect translations, no board is inserted, an incorrect board is
inserted, or an insane board is inserted.
This should re-establish the linkage between the internal ID and the port.
555-233-119
Description/ Recommendation
1. Retry the command at 1-minute intervals for a maximum of 5 times.
1. Retry the test ds1-loop UUCSS ds1/csu-loopback-tests command.
2. If the BLB test continues to fail, then replace the UDS1 circuit pack.
1. Ensure that the board translations are correct. Execute the add ds1
UUCSS command to administer the UDS1 interface if it is not already
administered.
2. If the board was already administered correctly, check the error log to
determine whether the board is hyperactive. If this is the case, the board
is shut down. Reseating the board will re-initialize the board.
3. If the board was found to be correctly inserted in step 1, then issue the
busyout board command.
4. Issue the reset board command.
5. Issue the release busy board command.
6. Issue the test board long command.
Continued on next page
Issue 5 October 2002
1825

Hide quick links:

Advertisement

Table of Contents
loading