Avaya DEFINITY Server CSI Maintenance Manual page 1796

Table of Contents

Advertisement

Maintenance Objects
Table 531. TEST #139 Blue Alarm Inquiry Test
Error
Test
Code
Result
ABORT
Internal system error
2000
ABORT
Response to the test was not received within the allowable time period. This
may be due to hyperactivity. Error Type 1538 in the error log indicates
hyperactivity. The hyperactive circuit pack is out of service and one or more
of the following symptoms may be exhibited.
When hyperactivity occurs, the circuit pack is isolated from the system, and
all of the trunks for this circuit pack are placed into the out of service state.
The system will try to restore the circuit pack within 15 minutes. When no
faults are detected for 15 minutes, the UDS1 interface circuit pack is restored
to normal operation. All of the trunks for the UDS1 interface circuit pack are
then returned to the in service state. Hyperactivity is often caused by the
associated facility. In such a case, faults (such as slips, misframes, or blue
alarms) would be entered in the error log. In addition, many hardware errors
would be logged against the associated trunk circuits. If the facility is OK and
the error occurs again after 15 minutes, replace the circuit pack.
2100
ABORT
Could not allocate the necessary system resources to run this test.
FAIL
The remote DS1 endpoint is out-of-service.
1
FAIL
The UDS1 Interface circuit pack detects a Line Loopback Alarm (LLB).
1794
If the UDS1 interface circuit pack connects to a T1 facility, call the vendor of
the T1 carrier to diagnose the remote DS1 endpoint.
If the UDS1 interface circuit pack connects directly to a switch, call the
system technician of the remote switch to diagnose the DS1 endpoint.
If the UDS1 interface circuit pack connects directly to a line-side terminating
device (for example, a PRI terminal adapter), call the vendor of the
terminating device to diagnose the equipment.
1796
Issue 5 October 2002
Description/ Recommendation
1. Retry the command at 1-minute intervals for a maximum of 5 times.
1. The UDS1-BD tests (such as Test #138 and Test #139) are aborting with
error code 2000.
2. The tests run on the ports of this circuit pack are returning a no board
result.
3. A busyout or a release command has no affect on the test results.
4. A list config command shows that the circuit pack and the ports are
properly installed.
1. Retry the command at 1-minute intervals for a maximum of 5 times.