GETASCII
10
! GETASCII
20
!———————————————————————————————————
30
! BASIC/IBASIC Program: ASCII query
40
! This program will read back the trace data values (401 data points
50
! for default FFT analysis) and display the first ten values on the
60
! screen. This program will also distinguish between BASIC/IBASIC.
70
!———————————————————————————————————
80
!
90
ON ERROR GOTO Not_ibasic
100
Device = 800
110
CLEAR Device
120
GOTO Start_prog
130
!
140 Not_ibasic:
150
Device=711
160 Start_prog:
170
OFF ERROR
180
!
190
!
200
ASSIGN @Analyzer TO Device
210
!
220
DIM A(400)
230
OUTPUT @Analyzer;"*RST"
240
OUTPUT @Analyzer;"ABORT;:INIT; *WAI"
250
OUTPUT @Analyzer;":INIT:CONT OFF"
260
!
270
!
280
!
290
OUTPUT @Analyzer;"FORM:DATA ASCII"
300
!
310
!
320
OUTPUT @Analyzer;"CALC1:DATA?"
330
!
340
!
350
IF Device=800 THEN OUTPUT @Analyzer;"DISP:PROG LOW"
360
!
370
!
380
FOR I=0 TO 400
390
!
400
!
410
!
420
ENTER @Analyzer USING "%,K";A(I)
430
IF I THEN PRINT "Data point ";I,A(I)
440
NEXT I
450
!
460
END
Example Programs