[SENSe:]WINDow[1|2|3|4]:EXPonential
Specifies the time constant for the exponential window function.
Command Syntax:
<number> ::= a real number (NRf data)
<unit> ::= [S]
<step> ::= UP|DOWN
<bound> ::= MAX|MIN
Example Statements:
Query Syntax:
Return Format:
Attribute Summary:
Description:
The time constant is used to calculate the exponential decay for the exponential window according to the
following formula:
The channel specifier, WINDow[1|2|3|4], is ignored. When the force window is specified (WIND
FORC), the exponential time constant is applied to all channels—even when the exponential window is
not specified.
Note
The first point in the time record is always considered to be time t=0.
[SENSe:]WINDow[1|2|3|4]:EXPonential {<number>[<unit>]}|
<step>|<bound>
limits:
3.8147E-6:9.9999E6
OUTPUT 711;"Sense:Window:Exponential .1"
OUTPUT 711;"WIND:EXP 2.5"
[SENSe:]WINDow[1|2|3|4]:EXPonential?
Real
Option:
not applicable
Synchronization Required:
Preset State:
+9.999E+003
SCPI Compliance:
t
no
confirmed
-t/
e
t
[SENSe:]
command/query
18-87