[SENSe:]AVERage:PREView:TIME
Specifies the amount of time the analyzer waits for a response in timed preview averaging.
Command Syntax:
<number> ::= a real number (NRf data)
<unit> ::= [S]
<step> ::= UP|DOWN
<bound> ::= MAX|MIN
Example Statements:
Query Syntax:
Return Format:
Attribute Summary:
Description:
The analyzer waits the specified amount of time for a response. If a response is not sent, the analyzer
accepts the time record.
Time is specified in seconds. Specify timed preview averaging with the AVER:PREV TIM command.
[SENSe:]AVERage:PREView:TIME {<number>[<unit>]}|<step>|
<bound>
limits:
0.1:3600.0
OUTPUT 711;":aver:prev:time 20"
OUTPUT 711;"SENS:AVERAGE:PREVIEW:TIME 60 S"
[SENSe:]AVERage:PREView:TIME?
Real
Option:
not applicable
Synchronization Required:
Preset State:
10 S
SCPI Compliance:
no