HCOPy
HCOPy:SOURce
Selects the portion of the analyzer's screen you want to plot.
Command Syntax:
Example Statements:
Query Syntax:
Return Format:
Attribute Summary:
Description:
This command is not valid when the specified device is a printer (HCOP:DEV PRIN). This command can
only be used with the HCOP:DEV PLOT command.
To plot everything currently displayed on the analyzer's screen, send HCOP:SOUR ALL;IMM .
Everything on the screen is plotted except the status line and the softkey menu.
To plot the displayed trace(s), send HCOP:SOUR TRAC;IMM. Traces are plotted without grid lines,
annotation or markers.
Send HCOP:SOUR MARK;IMM to plot the main marker for all displayed trace(s) The main marker
must be displayed (CALC:MARK ON) before it can be plotted. The marker is annotated with its X-axis
and Y-axis coordinates. The annotation appears above the marker.
Send HCOP:SOUR REF;IMM to plot the marker reference. The marker reference must be displayed
(CALC:MARK:MODE REL) before it can be plotted. The marker reference is annotated with its X-axis
and Y-axis coordinates. The annotation appears above the marker reference.
Send HCOP:SOUR GRID;IMM to plot the graticule only for all displayed traces. The grid is plotted
without the trace, markers or annotation
10-26
HCOPy:SOURce {ALL|TRACe|MARKer|REFerence|GRID}
OUTPUT 711;"HCOP:SOUR GRID"
OUTPUT 711;"hcopy:sour MARKer"
HCOPy:SOURce?
CHAR
Option:
not applicable
Overlapped:
no
Preset State:
ALL
SCPI Compliance:
instrument-specific
command/query