MMEMory:STORe:WATerfall
Saves the current waterfall display to a file on the specified disk.
Command Syntax:
<FILENAME> ::= '[<PATH>]<filename>'
<PATH> ::= <MSIS>[{DOS_DIR}]
<MSIS> ::= RAM:|NVRAM:|INT:|
<DOS_DIR> ::= \<DIR_NAME>\
<DIR_NAME> ::= ASCII characters
<filename> ::= ASCII characters (see beginning of chapter
Example Statements:
Attribute Summary:
Description:
This command saves a waterfall display to a file. The waterfall buffer must contain more than one trace.
The first parameter specifies which trace you are saving—TRAC1 for the waterfall appearing in trace box
A, TRAC2 for the waterfall appearing in trace box B, TRAC3 for the trace appearing in trace box C, or
TRAC4 for the waterfall appearing in trace box D. The second parameter specifies the disk and filename.
If the disk is not specified, the file is saved to the default disk.
If the filename you specify matches the name of another file on the disk, this command overwrites the old
file.
If the waterfall display is too large for the disk, an error, "Media full; File too large." Use the
MMEM:STORE CONT command to split the file over multiple disks. See the MMEM:STORE CONT
command for more information about splitting a time capture file on multiple disks.
Note
If you plan to transfer this file to a PC, refer to the MMEM:STOR:TRAC:FORM
command.
MMEMory:STORe:WATerfall {TRACe1|TRACe2|TRACe3|TRACe4,
<FILENAME>
EXT[,<select_code>[,<unit _number>]]:
(DOS only)
for <filename> restrictions)
OUTPUT 711;"MMEM:STORE:WATERFALL TRAC1, "LASTWAT'"
OUTPUT 711;"mmem:stor:wat trace2, 'int:mywat'"
Option:
not applicable
Synchronization Required:
Preset State:
not applicable
SCPI Compliance:
no
instrument-specific
MMEMory
command
15-39