test memory

test memory
Use test memory to run hardware diagnostic tests on any or all memory circuit
packs in the specified carrier. Both short and the long test are nondestructive
when testing memory.
Action/
Object
Qualifier
test
location
memory
short
long
repeat
number
clear
schedule
1
If no alarms are registered against the maintenance object then the test sequence is run only once. The long
clear option forces a clear of all alarms if no errors are encountered during testing. The short clear option only
clears alarms pertinent to tests in the short sequence.
2
See the Report Scheduler and System Printer feature specification for more details.
555-233-119
Qualifier Description
Physical location of the memory circuit
pack: PC (cabinet number (optional) and
carrier letter (a).
Option for a brief series of nondestructive
diagnostic tests.
Option for a longer, more comprehensive
test series (all nondestructive for this
command).
Number of times each test in the
sequence is repeated (1-100)
This option causes the test sequence
(short or long) to repeat until the alarm (if
any) is cleared or a single test in the
1
sequence fails.
Use the screen to schedule execution of
the command. The command is placed in
the command queue and is executed at
the specified time. The information
displayed by the command is sent to the
system printer instead of the screen.
Examples:
test memory
test memory a
test memory a schedule
test memory 1a2
test memory b1 sh
test memory b l r 25
test memory a l c
Logins
Defaults
init
cabinet = 1
inads
For SPE
craft
simplex
nms
systems,
carrier =a.
Remaining
defaults are
short with a
repeat of 1.
2
Issue 5 October 2002
Feature
Interactions
none