test environment
Feature Interactions
The long test recycles power in some specified cabinet on non-SPE and
maintenance board carriers and is destructive. Specifically, the "a" carrier
of PPNs does not have power recycled.
All port carriers are recycled, and service is interrupted for each port
carrier.
If a carrier containing an active tone-clock board is recycled, all ports in the
cabinet or port network will have service disrupted.
Output
The following example shows the output for test environment 1 to test a PPN
cabinet. The responses appear on a test-by-test basis with one line of data for
each test result.
test environment 1
Port
Maintenance Name
01
CABINET
01
EMG-XFER
01
EXT-DEV
01
EXT-DEV
01
RING-GEN
01
RING-GEN
Field descriptions
Port
Maintenance
Name
Alt. Name
Test No.
Result
Error Code
555-233-119
TEST RESULTS
Alt. Name Test No. Result
122
124
120
120
117
118
Port address (cabinet-carrier)
The name of maintenance object
Not applicable
The test being executed.
Test result: Pass, Abort, Fail, Disabled
Numeric code explaining why the release failed or aborted. See
the detailed list of the codes by test number for each MO.
Error Code
PASS
PASS
PASS
PASS
PASS
PASS
Issue 5 October 2002