test environment

Output
The following example shows the output for test external-device-alarm all. The
responses appear on a test-by-test basis with one line of data for each test result.
test eda-external-device-alarm all
Port
Maintenance Name
01major
01minor
01c1201
01c1202
Field definitions
Port
Maintenance Name
Alt. Name
Test No
Result
Error Code
test environment
Use test environment to run hardware diagnostic tests of the environment
monitoring and control, and emergency transfer functions of the Processor Port
Network (PPN) cabinet. Circuit packs involved are the Processor (PPN simplex
systems) and the Duplication Interface circuit packs. The tone/clock circuit pack is
involved in tests of the ring generator.
There are 8 Maintenance Objects involved in this testing:
1. CABINET tests air flow and temperature
2. EMG-XFER tests emergency transfer status
555-233-119
TEST RESULTS
Alt. Name Test No. Result
EXT-DEV
UPS1
EXT-DEV
UPS1
EXT-DEV
UPS1
EXT-DEV
Audix1
Port address (cabinet-carrier-slot-circuit)
The name of the maintenance object
The alternate means of identifying the maintenance object, in
this case, the administered (descriptive) name of the external
device alarm.
The test being executed
Test result: Pass, Abort, Fail, No Board, Disabled, or Extra Bd.
Numeric code explaining why the release failed or aborted. See
the detailed list of the codes by test number for each MO.
120
PASS
120
PASS
120
PASS
120
PASS
Issue 5 October 2002
Error Code
549