Maintenance Commands
3. EXT-DEV tests external (AUDIX, for example) alarm status for both the
SCC and MCC cabinet systems.
4. RING_GEN tests ringing voltage are tested in MCC cabinets only.
NOTE:
The processor carrier is not be recycled. All port carriers are recycled, and
service is interrupted for each port carrier. If a carrier containing an active
tone-clock board is recycled, all ports in the cabinet or port network will have
service disrupted.
Action/
Object
Qualifier
test
location
environment
short
long
repeat
number
clear
schedule
1
If no alarms are registered against the maintenance object then the test sequence is run only once. The long
clear option forces a clear of all alarms if no errors are encountered during testing. The short clear option only
clears alarms pertinent to tests in the short sequence.
2
See the Report Scheduler and System Printer feature specification for more details.
550
Issue 5 October 2002
Qualifier Description
Cabinet 1 = PPN
Option for a brief series of
nondestructive diagnostic tests.
Option for a longer, more
comprehensive series of both
destructive and nondestructive
diagnostic tests.
How many times each test in the
sequence is repeated (1-100)
This option causes the test
sequence (short or long) to repeat
until the alarm (if any) is cleared or
a single test in the sequence fails.
Use the screen to schedule
execution of the command. The
command is placed in the
command queue and is executed
at the specified time. The
information displayed by the
command is sent to the system
printer instead of the screen.
Examples:
test environment
test environment schedule
test environment 1 sh
test environment 1 l r 25
test environment 01 l r 25
test environment 01 l r 25
schedule
test environment 2 l c
test environment 3 c
Logins
Defaults
init
Cabinet = 1;
inads
test sequence
craft
= short; repeat
= 1