Maintenance Commands
Setting the Test Parameters
Enter test hardware-group and the object (board, carrier, etc.). The following
screen appears.
test hardware-group system
TEST HARDWARE-GROUP SELECTIONS
Select the desired options for the specified test.
Test sequence: short
Test repetition: repeat
Output OPTIONS:
Auto-page? n
Background? n
Failures? n
Field descriptions
Short (nondestructive) or long (more comprehensive, still
Test
nondestructive) test sequence
sequence
repeat - (1-99) each test is executed the number of times specified on
Test
each physical object.
Repetition
continuously -all tests on all the specified hardware run until
cancelled by either pressing the
cancel hardware-group command.
Repeat test sequence value (1-99). If the Test sequence field is set
count
to continuously, then this field disappears from the screen; if this field
is set to repeat, then the field appears.
Provides a new screen every time the SAT screen fills with test results.
Auto-page
(n / y). The screen does not scroll to accommodate new results. A new
screen appears after the current screen fills up.
If auto-page is not selected, the SAT screen does not refresh once it is
filled, and testing stops until the user enters the
or the
This option is not allowed if the background option is selected.
556
Issue 5 October 2002
HARDWARE OPTIONS:
All-ports? n
SPE-interchange? n
key to cancel the testing.
CANCEL
Page 1 of 1
count: 1
key or by executing the
CANCEL
key to continue
PAGE
555-233-119
Need help?