Avaya DEFINITY Server CSI Maintenance Manual page 538

Table of Contents

Advertisement

Maintenance Commands
Action/Object
Qualifier
test card-mem
location
short
long
repeat
number
clear
schedule
1
Carrier location required on command line
2
If no alarms are registered against the maintenance object then the test sequence is run only once. The long
clear option forces a clear of all alarms if no errors are encountered during testing. The short clear option only
clears alarms pertinent to tests in the short sequence. SEE WARNING BELOW.
3
See the Report Scheduler and System Printer feature specification for more details.
!
WARNING:
Since the "clear long" option clears all counters if tests pass, it is possible for
firmware counters to be cleared even when a problem exists. In some cases
customer service might degrade since calls may be routed over defective
equipment.
538
Issue 5 October 2002
Qualifier Description
Carrier location where memory card
resides: High or Critical Reliability (a
1
or b)
; duplicated (a, A, b, or B)
Option for a brief series of
nondestructive diagnostic tests.
Option for a longer, more
comprehensive test series (includes
a destructive test)
How many times each test in the
sequence is repeated (1-100)
This option causes the test sequence
(short or long) to repeat until the
alarm (if any) is cleared or a single
2
test in the sequence fails.
Use the screen to schedule
execution of the command. The
command is placed in the command
queue and is executed at the
specified time. The information
displayed by the command is sent to
the system printer instead of the
3
screen.
Examples:
test card-mem
test card-mem a l
test card-mem b sh r 2
test card-mem a sch
test card-mem a c
Feature
Logins
Defaults
Interactions
init
Test
See below
inads
sequence
craft
= short;
repeat = 1
555-233-119