7 Troubleshooting

7.1 Introduction to troubleshooting

Introduction
The product manual and the circuit diagram contains information that can be good
when troubleshooting.
For OmniCore, all event logs from the software can be seen on the FlexPendant,
or in Technical reference manual - Event logs for RobotWare 7.
Make sure to read through the section
Troubleshooting strategies
Work systematically
Keep a track of history
Product manual - IRB 6710
3HAC085695-001 Revision: A
Note
During troubleshooting with power on, the internal fan might cause dust to enter
the cabinet.
CAUTION
During troubleshooting with power on, make sure not to place your head too
close to the internal fan located on the door.
1 Isolate the fault to pinpoint the cause of the problem from consequential
problems.
2 Divide the fault chain in two.
3 Check communication parameters and cables.
4 Check that the software version is compatible with the hardware.
1 Take a look around to make sure that all screws, connectors, and cables are
secured, and that the robot and other parts are clean, not damaged, and
correctly fitted.
2 Replace one thing at a time.
3 Do not replace units randomly.
4 Make sure that there are no loose screws, turnings, or other unexpected
parts remaining after work has been performed.
5 When the work is completed, verify that the safety functions are working as
intended.
Make a historical fault log to keep track of problems over time.
Consult those working with the robot when the problem occurred.