ABB IRB 6710 Product Manual page 230

Table of Contents

Advertisement

5 Repair
5.3.3 Replacing the rear bearings on the balancing device
Continued
Restoring the balancing device and removing the Hydraulic press equipment, balancing device
1
Concluding procedure
1
230
Action
Restore the balancing device and remove
the press equipment according to instruc-
tions for the press equipment.
xx0900000813
Go to the user instructions enclosed with
the press tool.
DANGER
Handling the tool incorrectly will cause
serious injury.
Read and follow enclosed user instructions
for the tool.
Apply flange sealant and refit the cover
plate on the back of the balancing device.
Action
DANGER
Make sure all safety requirements are met
when performing the first test run. See
run after installation, maintenance, or repair
on page
94.
© Copyright 2023 ABB. All rights reserved.
Note
User instructions are enclosed with the
tool.
Hex socket head cap screw: M10x25 8.8-
A3F.
Tightening torque: 50 Nm.
Flange sealant for conical fittings: Loctite
5400 (or equivalent Loctite 577).
xx2200001330
Note
Test
Product manual - IRB 6710
3HAC085695-001 Revision: A

Advertisement

Table of Contents
loading

Table of Contents