ABB IRB 6710 Product Manual page 182

Table of Contents

Advertisement

5 Repair
5.2.3 Mounting instructions for sealings
Continued
3
4
Continues on next page
182
Action
Lubricate the sealing with grease just before fitting.
(Not too early - there is a risk of dirt and foreign
particles adhering to the sealing.)
Fill 2/3 of the space between the dust lip and the main
lip with grease. If the sealing is without dust lip, just
lubricate the main lip with a thin layer of grease.
Mount the sealing correctly with a mounting tool.
Never hammer directly on the sealing as this may
result in leakage.
© Copyright 2023 ABB. All rights reserved.
Note
Article number is specified in
Equipment on page
181.
A
B
xx2000000071
A Main lip
B Grease
C Dust lip
A
xx2000000072
A Gap
Product manual - IRB 6710
3HAC085695-001 Revision: A
C

Advertisement

Table of Contents
loading

Table of Contents