ABB IRB 6710 Product Manual page 339

Table of Contents

Advertisement

2
Refitting and connecting the SMB unit
1
2
3
4
Product manual - IRB 6710
3HAC085695-001 Revision: A
Action
Fit brake release unit into the electronic box and se-
cure with the screws.
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
ELECTROSTATIC DISCHARGE (ESD)
The unit is sensitive to ESD. Before handling the
unit read the safety information in section
unit is sensitive to ESD on page
Check the electronic box gasket.
Replace if damaged.
Fit the SMB unit into the electronic box.
© Copyright 2023 ABB. All rights reserved.
5.6.3 Replacing the brake release unit
Note
Torx pan head tapping screw:
Steel-Fe/Zn 8c M6x16
Tightening torque: 10 Nm.
xx2200001728
Note
The
48.
Cover, electronics:
3HAC081189-003 (Graphite White)
3HAC081189-004 (ABB Orange)
xx2200001724
5 Repair
Continued
Continues on next page
339

Advertisement

Table of Contents
loading

Table of Contents