ABB IRB 6710 Product Manual page 139

Table of Contents

Advertisement

Wear part
O-ring, G 1/2"
Required documents
Document name
Technical reference manu-
al - Lubrication in gearboxes
Floor-mounted robot: Draining the axis-1 gearbox
Use this procedure to drain the gearbox.
1
2
3
4
5
Product manual - IRB 6710
3HAC085695-001 Revision: A
Action
DANGER
Turn off all:
electric power supply
hydraulic pressure supply
air pressure supply
to the robot, before entering the safe-
guarded space.
WARNING
Handling gearbox oil involves several
safety risks, see
Gearbox lubricants (oil or
grease) on page
29.
Make sure that the oil temperature is +25°C
± 10°C.
CAUTION
The gearbox can contain an excess of
pressure that can be hazardous. Open the
oil plug carefully in order to let the excess
pressure out.
Remove the plug from the venting hole.
WARNING
Let the venting hole stay open during
draining and filling using the dispenser, to
avoid damaging vital parts in the gearbox.
© Copyright 2023 ABB. All rights reserved.
4.4.2 Changing the oil in axis-1 gearbox
Article number
Note
3HAC061327-059
Used on oil plug. Always replace when
refitting oil plug.
Document number
3HAC042927-001
Note
xx2200002147
4 Maintenance
Continued
Note
Continues on next page
139

Advertisement

Table of Contents
loading

Table of Contents