Refitting the cable harness in the base
1
2
3
4
Product manual - IRB 6710
3HAC085695-001 Revision: A
Action
Run the robot cable harness through the
frame recess and down through the protec-
tion tube.
Run the cabling through the base.
Make sure that the cables are not
twisted. Each cable must be in line
with its position on the base plate.
Make sure that the R1.SMB cable
will run on the correct side of the
R1.MP1, see the figure.
Make sure that the markings on the cables
are facing the base cover, when connected.
Connect connectors R1.MP and R1.SMB.
© Copyright 2023 ABB. All rights reserved.
5.8.1 Replacing the axis-1 gearbox
Note
xx2200001924
xx1300000736
Screw dimension for R1.MP: M6x25 A2-70
Tightening torque for R1.MP: 10 Nm.
Tightening torque for R1.SMB: 10 Nm.
xx2100001109
Continues on next page