5
Refitting the SMB unit
Refitting and connecting the SMB unit
1
2
3
4
Product manual - IRB 6710
3HAC085695-001 Revision: A
Action
Snap loose and remove the SMB unit.
Put the unit in an ESD bag.
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
ELECTROSTATIC DISCHARGE (ESD)
The unit is sensitive to ESD. Before handling the
unit read the safety information in section
unit is sensitive to ESD on page
Check the electronic box gasket.
Replace if damaged.
Fit the SMB unit into the electronic box.
© Copyright 2023 ABB. All rights reserved.
5.6.4 Replacing the SMB unit
Note
xx2200001724
Note
The
48.
Cover, electronics:
3HAC081189-003 (Graphite White)
3HAC081189-004 (ABB Orange)
xx2200001724
5 Repair
Continued
Continues on next page