ABB IRB 6710 Product Manual page 513

Table of Contents

Advertisement

5
Positioning the robot for refitting of the balancing device front shaft
1
2
3
Refitting the front shaft of the balancing device
1
2
3
Product manual - IRB 6710
3HAC085695-001 Revision: A
Action
If robot is equipped with DressPack.
Fit the mounting plate to the arm house.
Use locking liquid.
Action
Turn the power to the robot on temporarily.
Use caution and jog the robot to the calibration
position.
DANGER
Turn off all:
electric power supply
hydraulic pressure supply
air pressure supply
to the robot, before entering the safeguarded
space.
Action
Apply the lifting accessory to the balancing device
(if not already done).
Remove all residue of Loctite in the screw hole of
the shaft.
Wipe all contact surfaces inside the recess clean
from contamination.
© Copyright 2023 ABB. All rights reserved.
5.8.2 Replacing the axis-2 gearbox
Note
Locking liquid: - (Loctite 2400 (or equivalent
Loctite 243))
xx2300001036
Hex socket head cap screw: M10x16 8.8-
A3F (2 pcs)
Note
Note
Lifting shackle: SA-10-8-NA1
Lifting accessory (chain):
3HAC15556-1
Continues on next page
5 Repair
Continued
513