5 Repair
5.8.2 Replacing the axis-2 gearbox
Continued
10
11
12
13
Restoring the balancing device and removing the Hydraulic press equipment, balancing device
Continues on next page
516
Action
Fit the protection plug.
Unscrew both screws in link ear and fill the bear-
ing with grease from the upper hole until the
grease appears in the lower hole.
Refit the two screws and wipe clean from residual
grease.
Remove the lifting accessory from the balancing
device.
Action
Restore the balancing device and remove
the press equipment according to instruc-
tions for the press equipment.
xx0900000813
Go to the user instructions enclosed with
the press tool.
DANGER
Handling the tool incorrectly will cause
serious injury.
Read and follow enclosed user instructions
for the tool.
© Copyright 2023 ABB. All rights reserved.
Note
xx2200001460
Grease: 3HAA1001-294
xx2200001477
Note
User instructions are enclosed with the
tool.