xx1500001914
A
B
C
Periodic check of the calibration tool
If including the calibration tool in a local periodic check system, the following
measures should be checked.
xx1500000951
A
Periodic check of the calibration tool for the tool flange (3HAC058238-001)
If including the tool flange calibration tool in a local periodic check system, the
following measures should be checked.
Product manual - IRB 1100
3HAC064992-001 Revision: C
Tube insert
Plastic protection
Steel spring ring
•
Outer diameter within Ø12g4 mm, Ø8g4 mm or Ø6g5 mm (depending on
calibration tool size).
•
Straightness within 0.005 mm.
Outer diameter
•
Outer diameter within Ø5g5 mm.
•
Straightness within 0.005 mm.
© Copyright 20192020 ABB. All rights reserved.
6.4.2 Calibration tools for Axis Calibration
Continues on next page
6 Calibration
Continued
573