ABB Robotics IRB 1100 Product Manual page 458

Table of Contents

Advertisement

5 Repair
5.7.6 Replacing the axis-6 motor
Continued
2
Concluding procedure
1
2
458
Action
Refit the cover.
Action
Recalibrate the robot.
DANGER
Make sure all safety requirements are met when
performing the first test run.
© Copyright 20192020 ABB. All rights reserved.
Note
Screw: M3x8 12.9 Gleitmo
603+Geomet 500 (4 pcs)
Tightening torque: 1.2 Nm
xx1800002944
Note
Calibration is detailed in section
Calibration on page
559.
Product manual - IRB 1100
3HAC064992-001 Revision: C

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Irb 1100-4/0.475Irb 1100-4/0.58

Table of Contents