5 Repair
5.6.1 Replacing the housing
Continued
2
3
Disconnecting the axis-4 motor connectors
1
Continues on next page
318
Action
Valid for IRB 1100-4/0.475
Access the cable package locking screw on the
axis-4 gearbox from the wrist and then loosen the
locking screw.
Valid for IRB 1100-4/0.58
Remove the plug screw and washer on the ex-
tender unit to access the cable package locking
screw on the axis-4 gearbox and then loosen the
locking screw.
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.