ABB Robotics IRB 1100 Product Manual page 86

Table of Contents

Advertisement

4 Maintenance
4.3.1 Cleaning the IRB 1100
Continued
Cleaning with water and steam
Instructions for rinsing with water
ABB robots with protection types Standard, Foundry Plus, Wash, or Foundry Prime
can be cleaned by rinsing with water (water cleaner).
The following list defines the prerequisites:
I
Cables
Movable cables need to be able to move freely:
1
See
Cleaning methods on page 85
86
Maximum water pressure at the nozzle: 700 kN/m
Fan jet nozzle should be used, min. 45° spread
Minimum distance from nozzle to encapsulation: 0.4 meters
Maximum flow: 20 liters/min
Typical tap water pressure and flow
Remove waste material, such as sand, dust and chips, if it prevents cable
movement.
Clean the cables if they have a crusty surface, for example from dry release
agents.
for exceptions.
© Copyright 20192020 ABB. All rights reserved.
1
2
I
I
(7 bar)
Product manual - IRB 1100
3HAC064992-001 Revision: C

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Irb 1100-4/0.475Irb 1100-4/0.58

Table of Contents