ABB Robotics IRB 1100 Product Manual page 582

Table of Contents

Advertisement

6 Calibration
6.4.4 Axis Calibration - Running the calibration procedure
Continued
Restarting an interrupted calibration procedure
If the Axis Calibration procedure is interrupted before the calibration is finished,
the RobotWare program needs to be started again. Use this procedure to take
required action.
Situation
The three-position enabling device on the
FlexPendant has been released during robot
movement.
The RobotWare program is terminated with
PP to Main.
Axis Calibration with SafeMove option
To be able to run Axis Calibration, SafeMove needs to be unsynchronized. The
Axis Calibration routine recognizes if the robot is equipped with SafeMove and will
force SafeMove to unsynchronize automatically.
However, SafeMove may generate other warning messages anytime during the
Axis Calibration routine. When a warning message is displayed, tap Acknowledge
to confirm the unsynchronized state and continue Axis Calibration procedure.
After calibration
1
Continues on next page
582
CAUTION
SafeMove must be synchronized after the calibration is completed.
Action
Reinstall the protective cover on the fixed calibra-
tion pin on each axis, directly after the axis has
been calibrated.
Replace the cover with new spare part, if missing
or damaged.
© Copyright 20192020 ABB. All rights reserved.
Action
Press and hold the three-position enabling
device and press Play.
Remove the calibration tool, if it is installed,
and restart the calibration procedure from
the beginning. See
Starting the calibration
procedure on page
581.
If the calibration tool is in contact the robot
axis needs to be jogged in order to release
the calibration tool. Jogging the axis in wrong
direction will cause the calibration tool to
break. Directions of axis movement is shown
in
Calibration movement directions for all
axes on page 564
Note
xx1900001421
Calibration pin cover, 6 mm:
3HAC061926-001
Product manual - IRB 1100
3HAC064992-001 Revision: C