ABB Robotics IRB 1100 Product Manual page 396

Table of Contents

Advertisement

5 Repair
5.7.1 Replacing the axis-1 motor
Continued
2
3
Separating the cable package from the base
1
2
Continues on next page
396
Action
Disconnect the connectors.
FB1
MP1
Tip
Take photos of the connector and cable position
before disconnecting them, to have as a reference
when reconnecting.
Snap loose and remove the female head of the
connectors from the connector plate.
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
Remove the cable bracket.
© Copyright 20192020 ABB. All rights reserved.
Note
xx1800003613
xx1800003314
Note
xx1800003042
Product manual - IRB 1100