ABB Robotics IRB 1100 Product Manual page 348

Table of Contents

Advertisement

5 Repair
5.6.1 Replacing the housing
Continued
10
Reconnecting the axis-6 motor connectors
1
2
3
Continues on next page
348
Action
Remove the adjustment screw from the motor.
Action
Reconnect the connectors.
FB6
MP6
Tip
See the number markings on the connectors for
help to find the corresponding connector.
Route and secure the cabling with cable straps.
CAUTION
Correct cable routing is highly important.
If the cables are routed and secured incorrectly
the cables can be damaged.
Insert the cabling and connectors into the wrist.
© Copyright 20192020 ABB. All rights reserved.
Note
xx1900000007
Note
xx1800002994
Product manual - IRB 1100
3HAC064992-001 Revision: C

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Irb 1100-4/0.475Irb 1100-4/0.58

Table of Contents