5 Repair
5.6.1 Replacing the housing
Continued
3
4
5
6
Continues on next page
314
Action
Disconnect the air hoses.
For robots with safety lamp (option 3308-1)
Carefully pull out safety lamp connector behind
the air hose connectors and disconnect the con-
nector J5.UL.
For robots with CP/CS cabling
Disconnect the connector.
J5.C1
For robots with Ethernet cabling
Disconnect the connector J5.C2 using the tool.
© Copyright 20192020 ABB. All rights reserved.
Note
xx1800002945
xx1800002946
xx1800002947
J5.C2 connector assembly tool: -
xx1800002948
Product manual - IRB 1100
3HAC064992-001 Revision: C

Hide quick links: