5 Repair
5.4.1 Replacing the base
Continued
4
5
Refitting the connector interface plate
1
Continues on next page
226
Action
Valid for cabling with rear interface
Refit the bottom cover.
Valid for cabling with bottom interface (option
3309-1)
Refit the rear cover.
Action
Route and secure the cabling with cable straps.
CAUTION
Correct cable routing is highly important.
If the cables are routed and secured incorrectly
the cables can be damaged.
© Copyright 20192020 ABB. All rights reserved.
Note
Screw: M3x8 Steel 8.8-A2F (7 pcs)
Tightening torque: 1.2 Nm
xx1800003035
Screw: M3x8 12.9 Gleitmo
603+Geomet 500 (6 pcs)
Tightening torque: 1.2 Nm
xx1800003057