5
6
7
Product manual - IRB 1100
3HAC064992-001 Revision: C
Action
Install an M6x25 or longer adjustment screw to
the motor.
Note
Do not insert the entire screw to the hole.
Use a handheld tensiometer hooking to the screw
and pull the tensiometer to reach the initial refer-
enced force.
Secure the motor with the screws.
© Copyright 20192020 ABB. All rights reserved.
5 Repair
5.7.2 Replacing the axis-2 motor
Continued
Note
xx1900000010
Initial referenced force for used
belt: 68.18-75.04 N (for reference
only)
Initial referenced force for new belt:
97.4-107.2 N
xx1900000029
Tightening torque: 3.5 Nm
xx1800002493
Continues on next page
413
Need help?
Do you have a question about the IRB 1100 and is the answer not in the manual?
Questions and answers