ABB Robotics IRB 1100 Product Manual page 351

Table of Contents

Advertisement

Refitting the covers
1
2
3
Concluding procedure
1
2
Product manual - IRB 1100
3HAC064992-001 Revision: C
Action
Apply grease to the cable package, cover all
moving area of the package.
Apply grease to the covers that have contacting
area with the cable package.
Refit the covers.
Wrist covers
Lower arm cover
Lower arm support cover
Housing cover
Action
Recalibrate the robot.
DANGER
Make sure all safety requirements are met when
performing the first test run.
© Copyright 20192020 ABB. All rights reserved.
5 Repair
5.6.1 Replacing the housing
Continued
Note
Screw: M3x8 12.9 Gleitmo
603+Geomet 500
Tightening torque: 1.2 Nm
xx1800003611
Note
Calibration is detailed in section
Calibration on page
559.
351