Customer Connections - ABB Robotics IRB 1100 Product Manual

Table of Contents

Advertisement

3.5.2 Customer connections

Introduction to customer connections
The cables for customer connection are integrated in the robot and the connectors
are placed on the wrist and one at the base. There is one connector R2.C1 at the
wrist. Corresponding connector R1.C1 is located at the base.
There is also connections for Ethernet, one connector R2.C2 at the wrist and the
corresponding connector R1.C2 located at the base.
Hose for compressed air is also integrated into the manipulator. There are 4 inlets
at the base (R1/8") and 4 outlets (M5) on the wrist.
xx1900000131
Position
A
B
C
i
Product manual - IRB 1100
3HAC064992-001 Revision: C
(A)
(C)
Connection
Description
(R1)R2.C1
Customer power/signal
(R1)R2.C2
Customer power/signal
or Ethernet
Air
Max. 6 bar
The connector has 12 pins. Only pins 1 to 8 are available for use.
© Copyright 20192020 ABB. All rights reserved.
3 Installation and commissioning
3.5.2 Customer connections
(B)
(C)
(A)
(B)
(C)
Number
8 wires
8 wires
4
Value
i
30 V, 1.5 A
30 V, 1 A or 1 Gbits/s
Inner hose diameter 4 mm
Continues on next page
77

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Irb 1100-4/0.475Irb 1100-4/0.58

Table of Contents