2
Separating the cable package from the axis-1 gearbox
1
2
Pulling out the cable package
1
Product manual - IRB 1100
3HAC064992-001 Revision: C
Action
Remove the cable bracket.
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
Remove the pulley cover.
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
© Copyright 20192020 ABB. All rights reserved.
5 Repair
5.4.1 Replacing the base
Continued
Note
xx1800003042
Note
xx1800003043
Note
Continues on next page
209