ABB Robotics IRB 1100 Product Manual page 401

Table of Contents

Advertisement

Refitting the connector interface plate
1
2
Product manual - IRB 1100
3HAC064992-001 Revision: C
Action
Route and secure the cabling with cable straps.
CAUTION
Correct cable routing is highly important.
If the cables are routed and secured incorrectly
the cables can be damaged.
Valid for cabling with bottom interface (option
3309-1)
Refit the base adapter.
© Copyright 20192020 ABB. All rights reserved.
5 Repair
5.7.1 Replacing the axis-1 motor
Continued
Note
Screw: M3x8 Steel 8.8-A2F (7 pcs)
Tightening torque: 1.2 Nm
xx1800003056
Continues on next page
401

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Irb 1100-4/0.475Irb 1100-4/0.58

Table of Contents