Action
Route and secure the cabling with cable straps.
CAUTION
Correct cable routing is highly important.
If the cables are routed and secured incorrectly
the cables can be damaged.
Valid for cabling with bottom interface (option
3309-1)
Refit the base adapter.
© Copyright 20192020 ABB. All rights reserved.
5 Repair
5.7.1 Replacing the axis-1 motor
Continued
Note
Screw: M3x8 Steel 8.8-A2F (7 pcs)
Tightening torque: 1.2 Nm
xx1800003056