ABB Robotics IRB 1100 Product Manual page 178

Table of Contents

Advertisement

5 Repair
5.3.2 Replacing the lower cable package
Continued
Refitting the base cover
Notice that the procedure differs depending on if the connector interface is located
either at the rear or at the bottom of the base.
1
2
3
4
5
Continues on next page
178
Action
Apply grease to the cable package, cover all
moving area of the package.
Apply grease to the covers that have contacting
area with the cable package.
Route and secure the cabling with cable straps.
CAUTION
Correct cable routing is highly important.
If the cables are routed and secured incorrectly
the cables can be damaged.
Valid for cabling with rear interface
Refit the bottom cover.
Valid for cabling with bottom interface (option
3309-1)
Refit the rear cover.
© Copyright 20192020 ABB. All rights reserved.
Note
Screw: M3x8 Steel 8.8-A2F (7 pcs)
Tightening torque: 1.2 Nm
xx1800003035
Screw: M3x8 12.9 Gleitmo
603+Geomet 500 (6 pcs)
Tightening torque: 1.2 Nm
xx1800003057
Product manual - IRB 1100