5 Repair
5.7.2 Replacing the axis-2 motor
Continued
Removing the axis-2 motor
1
2
3
4
Continues on next page
408
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
Remove the swing support cover.
Remove the connector plate.
CAUTION
Be aware of the cablings that are attached to the
connector plate! The connector plate cannot be
removed completely until the connectors are re-
move from the plate.
Disconnect the connector.
J2.FB2
Tip
Take photos of the connector and cable position
before disconnecting them, to have as a reference
when reconnecting.
© Copyright 20192020 ABB. All rights reserved.
Note
xx1800002488
xx1800002489
xx1800002490
Product manual - IRB 1100