ZNB/ZNBT
[SENSe<Ch>:]SEGMent<Seg>:FREQuency:STARt
[SENSe<Ch>:]SEGMent<Seg>:FREQuency:STOP
[SENSe<Ch>:]SEGMent<Seg>:FREQuency:CENTer?
[SENSe<Ch>:]SEGMent<Seg>:FREQuency:SPAN?
[SENSe<Ch>:]SEGMent<Seg>:SWEep:POINts
Add / Insert / Delete / Delete All
The four buttons below the segment list extend or shorten the list.
"Add" adds a new segment to the end of the list.
The added segment covers a possible frequency gap between the preceding seg-
ment and the upper frequency limit of the analyzer. The "Start" frequency of the
new segment is set equal to the "Stop" frequency of the preceding segment. The
"Stop" frequency is equal to the upper frequency limit. The number of points is the
same as the number of points of the preceding segment.
"Insert" inserts a new segment before the active segment. The segment numbers
of all segments after the new segment are incremented by one.
The new segment covers a possible frequency gap between the two adjacent seg-
ments. A new segment which is inserted before segment no. 1 starts at the lower
frequency limit of the analyzer. The number of points is the same as the number of
points of the next segment.
"Delete" removes the selected segment from the list.
"Delete All" clears the entire segment list so it is possible to define or load a new
segmented sweep range.
Remote command:
[SENSe<Ch>:]SEGMent<Seg>:ADD
[SENSe<Ch>:]SEGMent<Seg>:INSert
[SENSe<Ch>:]SEGMent<Seg>:DELete[:DUMMy]
[SENSe<Ch>:]SEGMent<Seg>:DELete:ALL
Show Point List...
Opens a list of all active sweep points and their channel settings. All columns except
"Point", "Segment" and "Frequency" are displayed only if they are explicitly selected;
see
"Displayed Columns dialog"
Figure 5-9: Point List
User Manual 1173.9163.02 ─ 62
on page 434.
GUI reference
Sweep Softtool
433