  • Page 1 www.allice.de Allice Messtechnik GmbH ® R&S Handheld Vector Network Analyzer Getting Started (=RÉÝ2) 1334597902 Version 03...
  • Page 2 Allice Messtechnik GmbH ® This manual applies to the following R&S ZNH models with firmware version 1.10 and higher ● R&S ® ZNH4 (1321.1611.04) ● R&S ® ZNH8 (1321.1611.08) ● R&S ® ZNH18 (1321.1611.18) ● R&S ® ZNH26 (1321.1611.26) ●...
  • Page 3 www.allice.de Allice Messtechnik GmbH Safety Instructions Instrucciones de seguridad Sicherheitshinweise Consignes de sécurité Risk of injury and instrument damage The instrument must be used in an appropriate manner to prevent electric shock, fire, personal injury or instrument damage. ● Do not open the instrument casing. ●...
  • Page 4 www.allice.de Allice Messtechnik GmbH Gefahr von Verletzungen und Schäden am Gerät Betreiben Sie das Gerät immer ordnungsgemäß, um elektrischen Schlag, Brand, Verletzungen von Personen oder Geräteschäden zu verhindern. ● Öffnen Sie das Gerätegehäuse nicht. ● Lesen und beachten Sie die "Grundlegenden Sicherheitshinweise", die als gedruckte Broschüre dem Gerät beiliegen.
  • Page 5 www.allice.de Allice Messtechnik GmbH Safety instructions for rechargeable lithium ion batteries Risk of serious personal injury or even death. You must fully observe the following instructions in order to avoid serious personal injury ‒ or even death ‒ due to an explosion and/or fire.
  • Page 6 www.allice.de Allice Messtechnik GmbH Instrucciones de seguridad para baterías recargables de ión litio Posibilidad de lesiones graves que en determinadas circunstancias puede causar la muerte. Tenga en cuenta los siguientes avisos en caso de explosión y/o incendio para impedir lesiones graves en personas que, en determinadas circunstancias, podrían incluso causar la muerte.
  • Page 7 www.allice.de Allice Messtechnik GmbH Sicherheitshinweise für wiederaufladbare Li-Ion-Batterien Mögliche schwere Verletzungen, unter Umständen mit Todesfolge. Beachten Sie die folgenden Hinweise vollständig, um schwere Verletzungen von Personen - unter Umständen mit Todesfolge - durch Explosion und/oder Brand zu verhindern. 1. Batterien nicht zerlegen, öffnen, zerkleinern oder aus großer Höhe fallen lassen. Bei mechanischer Beschädigung besteht die Gefahr des Austritts von Chemikalien.
  • Page 8 www.allice.de Allice Messtechnik GmbH Consignes de sécurité pour batteries rechargeables lithium-ion Risque de blessures graves pouvant entraîner la mort. Respecter intégralement les consignes ci-dessous afin d'éliminer tout risque de blessures graves voire mortelles par suite d'explosion et/ou d'incendie. 1. Ne pas démonter, ouvrir ou découper les batteries ni les faire tomber d'une hauteur importante.
  • Page 9 www.allice.de Allice Messtechnik GmbH Customer Support Technical support – where and when you need it For quick, expert help with any Rohde & Schwarz product, contact our customer support center. A team of highly qualified engineers provides support and works with you to find a solution to your query on any aspect of the operation, programming or applications of Rohde &...
  • Page 10: Table Of Contents

    1.3 Calibration Certificate................6 1.4 Release Notes, Open Source Acknowledgment........ 6 1.5 Application Notes, Application Cards, Videos........6 2 Welcome to the R&S ZNH............. 7 3 Preparing for Use..............8 3.1 Putting into Operation................8 3.1.1 Unpacking and Checking the Instrument..........9 3.1.2 Accessory List..................10...
  • Page 11 www.allice.de Allice Messtechnik GmbH ® Contents R&S Getting Started 1334.5979.02 ─ 03...
  • Page 12: Documentation Overview

    You find the documents on the R&S ZNH product page at: http://www.rohde-schwarz.com/manual/znh Getting started manual Introduces the R&S ZNH and describes how to set up and start working with the product. The printed document is delivered with the instrument. User manual Contains the description of all instrument modes and functions.
  • Page 13: Data Sheet

    Application Notes, Application Cards, Videos Data Sheet The data sheet contains the technical specifications of the R&S ZNH. It also lists the options and their order numbers as well as optional accessories. The brochure provides an overview of the R&S ZNH and shows its specific char- acteristics.
  • Page 14: Welcome To The R&S Znh

    Welcome to the R&S ZNH R&S Welcome to the R&S ZNH The R&S ZNH is a new generation Rohde & Schwarz vector network analyzer developed to meet demanding customer requirements. Offering touchscreen input, the analyzer enhances user experience in making measurements fast and easy.
  • Page 15: Preparing For Use

    Putting into Operation Preparing for Use Putting into Operation This chapter describes the basic steps to be taken when setting up the R&S ZNH for the first time. Risk of injury due to disregarding safety information Observe the information on appropriate operating conditions provided in the data sheet to prevent personal injury or damage to the instrument.
  • Page 16: Unpacking And Checking The Instrument

    www.allice.de Allice Messtechnik GmbH ® Preparing for Use R&S Putting into Operation Risk of instrument damage during operation An unsuitable operating site or test setup can cause damage to the instru- ment and to connected devices. Ensure the following operating conditions before you switch on the instrument: ●...
  • Page 17: Accessory List

    3.1.3 Setting up the R&S ZNH The R&S ZNH is mainly used for diagnostic purpose during the installation of RF feeder cables and antennas for all kinds of radio transmitters. It can also be used to characterize both amplitude and phase measurements on complex test devices and discrete components with its S-parameters measurements.
  • Page 18 3. Insert the battery into the R&S ZNH. 4. Close the cover and screw back the thumb screws. You can operate the R&S ZNH with the AC adapter or the battery. Both are inclu- ded in the delivery. Getting Started 1334.5979.02 ─ 03...
  • Page 19: Using The Ac Adapter

    ● Attach the appropriate adapter to the power supply. Connect the AC adapter to the DC port on the left side of the R&S ZNH (item 1 of Figure 3-1). Make sure to fully insert the AC adapter plug into the DC port.
  • Page 20: Battery Operation

    (R&S HA-Z302, order number 1321.1340.02). You can connect the car adapter to the DC port. With the car adapter, you are able to charge the R&S ZNH via the car's cigarette lighter socket. A replacement battery (R&S HA-Z306, order num- ber 1321.1334.02) with the same capacity and charging time as the battery inclu-...
  • Page 21 3 = Power supply unit R&S HA-Z301 or car adapter R&S HA-Z302 Risk of traffic accidents, physical injury and property damage ● Turn off the R&S ZNH while driving or while the engine is on. ● Operation of the R&S ZNH via the cigarette lighter socket while driving or while the engine on is prohibited.
  • Page 22: Battery Maintenance

    Putting into Operation 3.1.6 Battery Maintenance The R&S ZNH comes with a lithium-ion battery. In general, these batteries are easy to handle. When you handle the battery, follow the instruction mentioned in the safety instructions and in the following chapters.
  • Page 23: Switching The Instrument On And Off

    12. ► Press [Power] key to switch on the instrument. During booting, the R&S ZNH displays a splash screen to indicate the opera- ble frequency range of the instrument. Depending on the frequency upgrade option installed, the respective splash screen is loaded.
  • Page 24 www.allice.de Allice Messtechnik GmbH ® Preparing for Use R&S Switching the Instrument On and Off Risk of losing data If a running instrument (without battery) is disconnected directly from the power cord, the instrument loses its current settings. Furthermore, program data may be lost.
  • Page 25: Instrument Tour

    ® Instrument Tour R&S Front View Instrument Tour This chapter describes the instrument in different views. Front View Figure 4-1: Front view of R&S ZNH RF port 1 BNC connector Headphone jack USB ports RF port 2 Touch-sensitive screen area...
  • Page 26: Top View

    LAN and mini USB port (behind protective cap) 21 = Micro-SD card slot (not visible as it is located behind the battery compartment) For a description of the keys, see "Front Panel Keys" in the R&S ZNH user man- ual. Instrument damage caused by cleaning agents Cleaning agents contain substances that may damage the instrument.
  • Page 27 For measurement examples, see CAT mea- surements in the R&S ZNH user manual. ● With two RF ports, it is possible to perform a full two-port measurement. For measurement examples, see VNA measurements in the R&S ZNH user man- ual. Risk of electrical shock To avoid electrical shock, the DC input voltage must never exceed the value specified on the housing.
  • Page 28 The level of the reference signal must be larger than 0 dBm. If there is no refer- ence signal present at the BNC connector, the R&S ZNH displays an appropriate message. Thus, measurements without a valid reference can be avoided.
  • Page 29 www.allice.de Allice Messtechnik GmbH ® Instrument Tour R&S Top View Risk of instrument damage To avoid damage to the tracking generator output, never apply currents greater than 600 mA or voltages greater than 20 V to the BNC connectors if the BNC connectors are not configured as BIAS output ports.
  • Page 30: Left View

    The R&S ZNH is supplied with power by the AC/DC transformer power supply via the DC connector. You can also use the DC connector to charge the battery. Kensington lock slot A Kensington lock can be anchored to the R&S ZNH housing to secure it to a workstation mechanically. Right View...
  • Page 31: Rear View

    For information on the different sections of the display area and touchscreen ges- tures, see "Screen Layout and Elements" and "Touchscreen Gesture Elements" in the R&S ZNH user manual. Getting Started 1334.5979.02 ─ 03...
  • Page 32 www.allice.de Allice Messtechnik GmbH ® Instrument Tour R&S Display Overview Figure 4-2: Display overview 1 = Title bar 2 = Measurement result view 3 = Measurement trace window 4 = Parameter view 5 = Softkey functions Risk of touchscreen damage during operation ●...
  • Page 33: Index

    www.allice.de Allice Messtechnik GmbH ® Index R&S Index Switching on and off the instrument ..16 AC adapter ..........12 Application cards ........6 Unpacking and checking the instrument ... 9 Application notes ........6 User manual ..........5 Battery insertion ........10 White papers ..........

This manual is also suitable for:

Znh4Znh8Znh18Znh26

Table of Contents