Save Settings in Recall Set
The "Select Ports" dialog preserves the selected and assigned port numbers. By
default (unchecked), these settings are global, i.e. they are identical for each recall set
and are not affected by a [Preset]. However you can also choose to preserve specific
settings for the current recall set (checked).
Note however that the settings are not persisted unless the "Select Ports" dialog is
closed using "OK".
5.6 Lines softtool
The "Lines" softtool allows you to define limits for the measurement results, visualize
them in the diagrams and activate/deactivate the limit check. The analyzer provides
upper, lower, ripple and circle limits. In addition, the "Lines" softtool provides functions
to limit complex diagrams to a user-defined "Display Circle" and to add user-defined
horizontal lines to cartesian diagrams.
Access: Trace – [Line] hardkey
Background information
Refer to
5.6.1 Limit Test tab
Defines limit lines for the measurement results (upper and lower limits), visualizes
them in the diagrams and activates/deactivates the limit check.
Limit lines are available for all cartesian diagram types; "dB Mag" limits can also be
checked in complex diagrams (Smith, Polar).
Background information
Refer to
User Manual 1173.9163.02 ─ 62
Chapter 4.4.1, "Limit
check",
Chapter 4.4.1, "Limit
check",
on page 144.
on page 144.
GUI reference
Lines softtool
373