The return value is of type string and returns the eye measurement results in csv for-
mat with decimal separator "." and field separator "," (see also
MEASurements).
Note that the full set of measurement results is only available for NRZ modulated gen-
erator signals (see
This command will raise an execution error if the active trace in the selected channel is
not an eye diagram.
Suffix:
<Chn>
Example:
Usage:
Options:
Manual operation:
User Manual 1173.9163.02 ─ 62
CALCulate<Chn>:EYE:INPut:MODulation
.
Channel number used to identify the active trace
For NRZ modulated generator signals
CALCulate:EYE:MEASurement:DATA? returns something
like
'Eye Measurements
Eye Minimum,-102.344 mV,
Eye Maximum,2.699 V,
Eye Base,277.189 µV,
Eye Top,2.597 V,
Eye Mean,1.298 V,
Eye Amplitude,2.596 V,
Eye Height,2.596 V,
Eye Width,10.000 ns,
Bit Period,10.000 ns,
Rise Time,115.000 ps,
Fall Time,115.000 ps,
Jitter Pk-Pk,50.125 ps,
Jitter RMS,0.000 s,
Duty Cycle Dist,0.000 s,
Duty Cycle Pct,0.000 %,
Crossing Percent,50.000 %,
Opening Factor,1.000 ,
SNR,0.000 '
For PAM modulated generator signals a reduced set of mea-
surement results is returned:
'Eye Measurements
Eye Minimum,-2.909 V,
Eye Maximum,2.997 V,
Eye Base,-2.734 V,
Eye Top,2.734 V,
Eye Mean,0.000 V,
Eye Amplitude,5.468 V'
Query only
R&S ZNB/ZNBT-K20
See
"Display Measurements"
Command reference
SCPI command reference
MMEMory:STORe:EYE:
on page 864).
on page 690
878