If the active trace is an eye diagram, the "Measurements..." button brings up a dialog
which allows to select and configure the eye measurements to be displayed (if
Measurements
The following measurement results can be selectively enabled/disabled:
"Basic" – Eye Minimum, Eye Maximum, Eye Base, Eye Top, Eye Mean, Eye Ampli-
tude, Eye Height, Eye Width
For PAM signals (see
not available.
"Time" – Bit Period, Rise Time, Fall Time, Jitter Pk-Pk, Jitter RMS, Duty Cycle Dist,
Duty Cycle Pct, Crossing Percent, Opening Factor, SNR
For PAM signals these results are not available.
For a description of the result values, see
Furthermore it is possible to change the Rise (and Fall) Time definition for the eye
measurement from the standard 10–90% (90–10%) step to any other "Start
Value"/"Stop Value" pair.
Remote command:
CALCulate<Chn>:EYE:MEASurement:TTIMe:THReshold
Export Measurements...
If the active trace is an eye diagram, the "Export Measurements" button opens the
"Export Eye Measurements – ASCII Files" dialog that allows to save the
Results
User Manual 1173.9163.02 ─ 62
is enabled).
"Modulation"
to an ASCII file.
on page 693) Eye Height and Eye Width are
"Eye Diagram Results"