CALCulate<Chn>:MARKer<Mk>:FUNCtion:BWIDth:MODE <BandfilterType>
Selects the bandfilter search mode. In contrast to manual control, bandfilter tracking is
not automatically activated.
Suffix:
<Chn>
<Mk>
Parameters:
<BandfilterType>
Example:
Manual operation:
CALCulate<Chn>:MARKer<Mk>:FUNCtion:CENTer
CALCulate<Chn>:MARKer<Mk>:REFerence:FUNCtion:CENTer
Sets the center of the sweep range to the stimulus value of the related marker (marker
<Mk> or the reference marker on the active trace of channel <Chn>).
Suffix:
<Chn>
<Mk>
Example:
Usage:
Manual operation:
User Manual 1173.9163.02 ─ 62
.
Channel number used to identify the active trace
This numeric suffix is ignored and may be set to any value
because the bandfilter search functions always use markers M1
to M4.
BPASs | BSTop | BPRMarker | BSRMarker | BPABsolute |
BSABsolute | NONE
Bandfilter search type:
BPASs – Bandpass Search Ref to Max
BSTop – Bandstop Search Ref to Max
BPRMarker – Bandpass Search Ref to Marker
BSRMarker – Bandstop Search Ref to Marker
BPABsolute – Bandpass Absolute Level
BSABsolute – Bandstop Absolute Level
NONE – deactivate bandfilter search, result off
*RST:
NONE
See
CALCulate<Chn>:MARKer<Mk>:BWIDth
See
"Bandpass Ref to Max"
.
Channel number used to identify the active trace
Marker number (ignored for reference markers)
*RST; :CALC:MARK ON
Create marker 1 in the center of the current sweep range and
assign it to trace no. 1.
CALC:MARK:FUNC:CENT
Leave the sweep range unchanged.
Event
See
"Center = Marker / Start = Marker / Stop = Marker / Span =
Marker"
on page 411
Command reference
SCPI command reference
on page 407