In "Point based" mode, the x-axis shows all sweep points with equal spacings.
Gaps between sweep segments are minimized; no diagram space is "wasted" on
unused frequency ranges. Point-based mode is indicated in the channel line.
The example below shows a segmented frequency sweep with two segments. The first
segment ranges from 1 GHz to 1.4 GHz; the second segment from 2 GHz to 3 GHz.
Both segments contain 11 sweep points. In point-based mode (lower diagram), all
sweep points are equidistant.
Tip: Overlapping limit line and ripple limit line segments are not displayed when a
point-based x-axis is active; see
on page 145.
Remote command:
[SENSe<Ch>:]FREQuency:SEGMent:AXIS
5.10.2.2
Define Segments dialog
The "Define Segments" dialog defines all channel settings for a
sweep and imports or exports segmented sweep settings.
Access: Channel – [Sweep] > "Sweep Type" > "Define Segments..."
The dialog contains a table to edit the individual segments of the sweep range. Use the
Displayed Columns dialog
User Manual 1173.9163.02 ─ 62
Chapter 4.4.1.1, "Rules for limit line
to select the columns to be displayed and edited.
GUI reference
Sweep Softtool
definition",