CALCulate<Chn>:RIPPle:CLEar
CALCulate<Chn>:RIPPle:CONTrol:DOMain
CALCulate<Chn>:RIPPle:DATA
CALCulate<Chn>:RIPPle:DELete:ALL
CALCulate:RIPPle:DISPlay:RESult:ALL[:STATe]
CALCulate<Chn>:RIPPle:DISPlay[:STATe]
CALCulate<Chn>:RIPPle:FAIL?
CALCulate:RIPPle:FAIL:ALL?
CALCulate<Chn>:RIPPle:RDOMain:FORMat
CALCulate<Chn>:RIPPle:SEGMent:COUNt?
CALCulate<Chn>:RIPPle:SEGMent<Seg>:LIMit
CALCulate<Chn>:RIPPle:SEGMent<Seg>:RESult?
CALCulate<Chn>:RIPPle:SEGMent<Seg>[:STATe]
CALCulate<Chn>:RIPPle:SEGMent<Seg>:STIMulus:STARt
CALCulate<Chn>:RIPPle:SEGMent<Seg>:STIMulus:STOP
CALCulate<Chn>:RIPPle:SOUNd[:STATe]
CALCulate<Chn>:RIPPle:STATe
CALCulate<Chn>:RIPPle:STATe:AREA
CALCulate<Chn>:RIPPle:CLEar
Resets the limit check results for the ripple test.
Suffix:
<Chn>
Usage:
Manual operation:
CALCulate<Chn>:RIPPle:CONTrol:DOMain <SweepType>
Deletes the existing ripple limit ranges and (re-)defines the physical units of the stimu-
lus values of the ripple limit lines. The unit of the ripple limit is defined via
CALCulate<Chn>:RIPPle:RDOMain:FORMat.
Suffix:
<Chn>
Setting parameters:
<SweepType>
User Manual 1173.9163.02 ─ 62
......................................................................................977
......................................................................977
.......................................................................................978
..............................................................................979
............................................................... 979
....................................................................... 979
.......................................................................................980
..........................................................................................980
....................................................................981
....................................................................981
............................................................... 982
........................................................................984
......................................................................................984
............................................................................ 985
.
Channel number used to identify the active trace
Event
See
"Clear Test"
on page 383
.
Channel number used to identify the active trace
FLIN | FLOG | FSEG | FSINgle | TLIN | TLOG | PLIN | PLOG |
PSINgle
Keywords for the units of the stimulus values; frequency, power,
and time units.
The selected unit must be compatible with the sweep type (see
[SENSe<Ch>:]SWEep:TYPE
FLOG, FSEG and FSINgle, s for TLIN and TLOG, dBm for PLIN,
PLOG and PSINgle. Otherwise the ripple limit lines cannot be
displayed and no ripple limit check is possible.
*RST:
FLIN
Command reference
SCPI command reference
...........................................................982
........................................................... 983
...............................................983
............................................... 983
on page 1328): Hz for FLIN,
977

Advertisement

Table of Contents
loading

Table of Contents